Copyright 2025. KOSORI
All Rights Reserved.

시험인증센터

보유시험설비

Vertical Type Fire Test Furnace
수직형 화재 실증시험 화덕설비
Objectives Fire performance and reliability testing of vertical type structural systems or components
(e.g., walls, doors, windows, penetration seals) in fires with or without mechanical loads in the vertical direction Fire performance and reliability testing of passive fire protection system for vertically positioned systems
Features of Test Facility Rectangular type vertical furnace is used to apply the elevated temperature due to fires.
Temperature control is made in accordance with the designated temperature versus time history as per international standards or other fire scenarios.
Hydraulic actuator is installed to apply the mechanical loads up to 2MN and/or 150mm stroke in the vertical direction.
Watch holes are allocated to close-eye monitor during testing.
Remote control and automatic test data measurements are made.
Specification Maximum specimen size: W4.5 x H4.5 (m)
Exhaust gas treatment system: 1,200m3/min
Maximum temperature: 1,430 deg. C
Maximum loading capacity: 2MN and 150mm stroke
Gas burner: Max. 463kW
Data acquisition sampling rate: 10 S/s
Sample Test Standards ASTM E 119 : Standard test methods for fire tests of building construction and materials
ISO 834-1 : Fire-resistance tests - Elements of building construction
- Part 1: General requirements
ISO 834-4 : Fire-resistance tests - Elements of building construction
- Part 4: Specific requirements for loadbearing vertical separating elements
ISO 834-8 : Fire-resistance tests - Elements of building construction
- Part 8: Specific requirements for non-loadbearing vertical separating elements
BS EN 1363-1 : Fire resistance tests - Part 1: General requirements
IMO Res. MSC. 307(88) : Fire resistance test procedures for “A”, “B” and “F” class divisions - Annex 1 / Part 3
UL 1709 : Rapid rise fire tests of protection materials for structural steel