Copyright 2025. KOSORI
All Rights Reserved.

시험인증센터

보유시험설비

Blast Wall / Door / Window Test Facility
방폭벽 / 문 / 창 실증시험 설비
Objectives Blast performance and reliability testing of industry products (e.g., blast walls, doors, and windows) in explosions
Features of Test Facility Four models can be tested at the same time.
Remote control and automatic test data measurements are made.
Specification Test frame size: L12 x W6 x H4 (m)
Data acquisition: 1 MS/s, 32 ch.
Gas analyzer: 20ppb ~ 30ppm
Maximum blast pressure: 2bar (operational), 5bar (structure)
Maximum test model sizes: L2 x W4, L4 x W4, L4 x W6, L4 x W8 (m)
Sample Test Standards ASTM F 2247 : Standard test method for metal doors used in blast resistant applications (Equivalent static load method)
ISO 16933 : Glass in building - Explosion-resistant security glazing test and classification for arena air - blast loading
EN 13541 : Glass in building - Security glazing testing and classification of resistance against explosion pressure
EN 13124-1 : Windows, doors and shutters - Explosion resistance test method
- Part 1: Shock tube
EN 13124-2 : Windows, doors and shutters - Explosion resistance test method
- Part 2: Range test